Product Overview
The DO-EC05 Alarm Output and Integrated Fire Control Expansion Controller is a specialized add-on module designed for access control systems requiring fail-safe fire alarm integration and multi-zone alarm output management. This expansion panel enables system integrators and project contractors to consolidate fire control signaling, intrusion detection response, and door lock coordination into a single, offline-capable access control architecture. Instead of deploying separate alarm panels and fire relay boards, the DO-EC05 provides a unified hardware interface that communicates directly with the host access controller, reducing wiring complexity, panel enclosure requirements, and per-door installation cost.
Commercial facility managers, security system distributors, and industrial safety officers choose this module when they need to comply with fire code requirements for automatic door release without replacing their existing access control infrastructure. The board accepts four independent alarm input channels and delivers four programmable relay output channels, each configurable for event-specific responses such as forced entry alerts, prolonged door open warnings, duress entry triggers, invalid credential notification, and fire emergency unlocking. By centralizing these functions on one expansion board, the system reduces the number of enclosures, power supplies, and communication cables required per deployment, which directly lowers hardware procurement costs and installation labor for large-scale projects.
Product Advantages
The DO-EC05 delivers measurable commercial value for security integrators and wholesale buyers who need repeatable, code-compliant fire alarm integration across multiple sites. Its primary advantage is the elimination of separate fire control panels for access-controlled doors. When a fire alarm signal is received on any of the four input channels, the module automatically triggers all connected doors to unlock, ensuring egress compliance without requiring additional fire relay modules or centralized fire alarm panel integration. This single-board approach reduces bill-of-materials cost per door by approximately 30 percent compared to deploying standalone fire alarm interface boards for each controlled opening.
For system integrators managing multi-building campus deployments or retail chain rollouts, the ability to define which alarm outputs correspond to which doors within the software provides deployment flexibility without hardware reconfiguration. The 0-to-6000-second programmable output delay allows tailoring door release timing to specific egress scenarios, such as staggered unlocking in high-security zones or delayed relocking after fire alarm reset. Distributors and project contractors benefit from the module’s compatibility across multiple DO RFID Reader controller models, which simplifies inventory management—one expansion board SKU serves various site requirements rather than stocking model-specific boards for each controller variant.
Manufacturing consistency is another core advantage. As a factory-produced expansion module, each DO-EC05 board undergoes in-house functional testing of all four input channels, four relay outputs, and communication handshake with the host controller before shipment. This batch-level quality assurance ensures that bulk orders for multi-site deployments receive identical performance characteristics, eliminating site-to-site variation in alarm response timing or relay switching reliability. For OEM customers, the board’s straightforward interface enables rapid integration into custom enclosure designs or branded security solution kits without requalifying the entire access control system.
Key Features
- Four-Channel Alarm Output with Programmable Assignment – Each of the four relay outputs can be independently assigned to any door or door group controlled by the host access controller. This allows site-specific alarm response mapping without hardware jumper changes.
- Integrated Fire Control Interface – Direct connection to fire alarm panels or manual pull stations. Upon receiving a fire signal, the controller automatically unlocks all doors in the affected zone and generates a time-stamped fire alarm event record for post-event review and compliance documentation.
- Multi-Event Alarm Linkage – Supports programmable output triggers for illegal intrusion, prolonged door open (adjustable 0–6000 seconds), duress entry, valid card link-open, invalid card attempt, and fire alarm. Each event type can activate one or more relay outputs independently.
- Per-Output Delay Configuration – Each relay output channel supports independent delay timing from 0 to 6000 seconds, enabling sequenced door unlocking, delayed alarm notification, or staged egress coordination.
- Duress Entry Detection with Password Change Support – Authorized users can change the anti-intimidation password through the software interface. When a duress credential is used, the module triggers the assigned alarm output silently without alerting the person at the door.
- Compatibility with DO-2000 Series Controllers – Works with DO-WG01, DO-WG02, DO-WG04, DO-T01, DO-T02, DO-T04, DO-RS01, DO-RS02, and DO-RS04 access controllers for unified system architecture.
- Software Requirement – Requires management software version V6.6 or higher to support full alarm output and fire control configuration.
- Status Indication – Onboard power and relay status LEDs provide immediate visual confirmation of module operational state and communication link integrity with the host controller.
Technical Specifications
| Product Model | DO-EC05 |
| Product Name | Enhanced Alarm Output and Integrated Fire Control Expansion Panel |
| Applicable Controllers | DO-WG01 / DO-WG02 / DO-WG04, DO-T01 / DO-T02 / DO-T04, DO-RS01 / DO-RS02 / DO-RS04 |
| Input Channels | 4-way alarm input |
| Output Channels | 4-way relay alarm output |
| Supported Alarm Events | Invalid break-in alarm, long time unlocking alarm, intimidation break-in alarm, unlocking linkage output, invalid card swiping alarm, integrated fire control alarm |
| Fire Control Response | Automatic door unlock on fire signal received; fire alarm event recorded in system log |
| Output Delay Range | 0–6000 seconds, configurable per output channel |
| Long Time Unlocking Alarm Range | 0–6000 seconds |
| Duress Function | Supports anti-intimidation password change via software |
| Software Requirement | V6.6 or higher |
| Certification | CE |
| Accessories Included | User Manual, warranty card, necessary connecting parts for panel installation |
Industrial Applications
The DO-EC05 is deployed in commercial, industrial, and institutional environments where fire code compliance and multi-zone alarm monitoring must operate within a unified access control framework. Typical installations include office building perimeter doors, manufacturing facility emergency exits, warehouse personnel gates, laboratory restricted areas, data center server room entrances, and educational campus secure zones. System integrators use this module when retrofitting existing access control systems to meet updated fire safety regulations, as the board integrates directly with the existing controller without requiring new head-end hardware or rewiring of the entire door network.
For facilities with mixed-security zones, the per-door programmable alarm assignment enables a single expansion board to serve both high-security areas requiring immediate lockdown on intrusion detection and general access areas where only fire alarm unlock is needed. Industrial plant safety managers value the long-duration door-open alarm feature for monitoring dock doors or equipment access points that must not remain unsecured beyond a set time window. The four-input design also supports connection to auxiliary sensors such as window contacts, motion detectors, or glass break sensors, allowing the access control system to double as a basic intrusion detection panel without purchasing a separate security system.
Large-scale deployment projects—such as multi-tenant office towers, hospital campuses, or government facilities—benefit from the module’s consistent behavior across hundreds of doors. Because each DO-EC05 is factory-tested and follows the same firmware logic, site acceptance testing proceeds faster and troubleshooting is simplified. Wholesale buyers supplying security contractors across multiple regions can stock one expansion board model that works with multiple controller types, reducing inventory carrying costs and eliminating the risk of shipping incompatible hardware to job sites.
OEM / ODM Manufacturing Support
DO RFID Reader offers OEM and ODM manufacturing for the DO-EC05 expansion controller, enabling security brands, system integrators, and solution providers to integrate this alarm and fire control functionality into their own product lines. OEM customization options include private-label enclosure design with customer branding, custom PCB silkscreen and labeling, tailored firmware configurations for specific alarm event mapping, and modified output delay ranges to match proprietary system requirements. ODM services extend to complete board redesign for integration into custom panel assemblies, multi-board rack mount kits, or combined controller-expansion units.
For distributors requiring consistent product identity across their catalog, OEM production ensures that every DO-EC05 shipped carries your brand, part number, and packaging. Batch traceability is maintained through factory-assigned serialization, and each production run includes pre-shipment functional testing of all input and output channels. Minimum order quantities for OEM production start at 100 units per configuration, with lead times typically ranging from 15 to 25 working days depending on customization complexity and current factory capacity. Technical documentation including wiring diagrams, software integration notes, and compliance declarations is provided in both English and Chinese to support global distribution.
Factory Production Advantages
DO RFID Reader operates a dedicated production facility with over 20 years of manufacturing experience in access control and RFID hardware. The DO-EC05 is produced on a controlled assembly line with automated soldering, optical inspection, and functional test stations. Each board undergoes a 24-hour burn-in test under simulated alarm cycling to verify relay contact reliability and communication stability with the host controller. This production process ensures that bulk orders for 500 or 1000 units deliver consistent switching performance and identical firmware behavior across every board in the shipment.
Production capacity for the DO-EC05 series supports monthly volumes exceeding 10,000 units, with the ability to scale for large project orders within 10 working days. Incoming component inspection verifies relay specifications, input optocoupler sensitivity, and PCB quality before assembly begins. Warehousing maintains safety stock of critical components—including relays, terminal blocks, and communication ICs—to prevent supply chain disruptions during high-volume production runs. For long-term wholesale agreements, DO RFID Reader offers scheduled production slots with fixed pricing for 6-month or 12-month supply commitments, giving distributors predictable cost structures for project quoting.
Bulk Supply & Project Deployment Support
Wholesale buyers and project contractors benefit from tiered pricing based on order quantity, with volume breaks at 50, 200, 500, and 1000 units per shipment. Each bulk order ships with batch-testing documentation, individual board packaging with anti-static protection, and consolidated packing for freight efficiency. For multi-site deployments, DO RFID Reader can pre-configure each DO-EC05 with site-specific firmware settings—such as default output timing, alarm event mapping, and fire unlock behavior—before shipment, reducing on-site programming time for installation crews.
Technical support for project integration includes wiring diagrams, software configuration guides, and remote assistance for initial system commissioning. For large-scale rollouts exceeding 50 boards, a factory application engineer can provide pre-shipment system compatibility verification against the customer’s controller firmware version and software build. Replacement units for field failures are shipped within 48 hours during the warranty period, ensuring that project timelines are not delayed by single-board issues. Export documentation such as CE declaration, commercial invoice, and packing list is provided with every shipment, and DO RFID Reader supports EXW, FOB, CIF, and CFR trade terms to accommodate global procurement requirements.
Frequently Asked Questions
Q: Which access controllers are compatible with the DO-EC05 expansion board?
A: The DO-EC05 is compatible with DO-WG01, DO-WG02, DO-WG04, DO-T01, DO-T02, DO-T04, DO-RS01, DO-RS02, and DO-RS04 controllers. The management software must be version V6.6 or higher.
Q: How many alarm inputs and outputs does the board support?
A: The board provides four alarm input channels and four relay output channels, each independently programmable for event type and delay timing.
Q: Can the DO-EC05 be used for fire code compliance?
A: Yes. When connected to a fire alarm panel or manual pull station, the board receives the fire signal and automatically unlocks all doors in the controlled zone while recording the event in the system log.
Q: What is the delay time range for alarm outputs?
A: Each output channel can be configured with a delay from 0 to 6000 seconds, allowing sequenced door unlocking or delayed alarm response.
Q: Is OEM customization available for this product?
A: Yes. DO RFID Reader offers OEM and ODM services including custom enclosure branding, PCB labeling, firmware configuration, and packaging. Minimum order quantities apply for custom configurations.
Q: What are the minimum order quantities for bulk supply?
A: Volume pricing is available at 50, 200, 500, and 1000 units. Production lead times range from 7 to 30 working days depending on order quantity and customization requirements.
Q: Does the board support duress entry detection?
A: Yes. The system supports anti-intimidation password functionality, and the duress password can be changed through the software interface. When a duress credential is used, the assigned alarm output is triggered silently.
Q: What documentation is included with the board?
A: Each DO-EC05 includes a user manual, warranty card, and all necessary connecting parts for panel installation. Technical support documentation is available for system integrators.
For detailed technical specifications, OEM project consultation, or bulk pricing for the DO-EC05 Alarm Output and Integrated Fire Control Expansion Controller, contact DO RFID Reader at info@dorfidreader.com.